CFGZW - DELO GEAR LUBRICANT SAE 85W-140, CPS224504

Product Identification

Product ID:DELO GEAR LUBRICANT SAE 85W-140, CPS224504
MSDS Date:12/21/1990
FSC:9150
NIIN:00N077619
MSDS Number: CFGZW

Responsible Party
CHEVRON ENVIRONMENTAL HEALTH CENTER INC
RICHMOND, CA 94804
US

Emergency Phone: 800-457-2022; 510-233-3737

Info Phone: 800-582-3835

Cage: 0AHD1

Contractor
CHEVRON ENVIRONMENTAL HEALTH CENTER INC
4054 RICHMOND, CA 94804 US

Telephone: 800-582-3835

Cage: 0AHD1

Ingredients

MINERAL OIL, PETROLEUM DISTILLATES, HYDROTREATED (SEVERE)

CAS: 64742-54-7

RTECS: PY8035501

Fraction By Weight: <90%

OSHA PEL 5 MG/M3 (MFR)

ACGIH TLV: 5 MG/M3 (MFR)


PARAFFINIC) (COMBINED W/ING 3)

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


MINERAL OIL; (HYDROTREATED BRIGHT STOCK BASE OIL) (COMBINED

CAS: 72623-83-7

Fraction By Weight: <90%

OSHA PEL 5 MG/M3 (MFR)

ACGIH TLV: 5 MG/M3 (MFR)


ADDITIVES

Fraction By Weight: <10%

OSHA PEL N/K

ACGIH TLV: N/K


RESPONDING TO LARGER RELEASES.

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE/SKIN CONT:THIS SUBSTANCE IS NOT
EXPECTED TO CAUSE PRLNG/SIGNIFICANT IRRIT. THIS HAZ EVALUATION IS
BASED ON DATA FROM SIMILAR MATLS. DERMAL TOX/INHAL/INGEST:SYSTEMIC
TOX OF THIS SUBSTANCE HAS NOT B EEN DETERMINED. HOWEVER, IT SHOULD
BE PRACTICALLY NON-TOX TO INTERNAL ORGANS IF IT GETS ON SKIN, IS
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INHALED OR IS SWALLOWED. THIS HAZARD
EVALUATION IS BASED ON DATA FROM SIMILAR MATERIALS. ADDITIONAL
HEALTH DATA:THIS PRODUCT CONTAINS PETROLEUM BASE OILS WHICH MAY BE
REFINED BY VARIOUS PROCE SSES INCLUDING SEVERE SOLVENT EXTRACTION,
SEVERE HYDROCRACKING OR SEVERE HYDROTREATING.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BRTHG (GIVE O*2/ARTF RESP)
. EYES:FLUSH W/FRESH WATER FOR AT LST 15 MINS. REMOVE CONTACT
LENSES IF WORN. SKIN:WASH THORO W/SOAP & WATER. REMOVE & WASH
CONTAM C LTHG. INGEST:GIVE WATER/MILK TO DRINK &TELEPHONE FOR MED
ADVICE. CONSULT MED PERS BEFORE INDUCING VOMIT. IF MED ADVICE
CANNOT BE OBTAINED, THEN TAKE PERS & PROD CNTNR TO NEAREST MED EMER
(SUPP DATA)

Fire Fighting

Flash Point Method:COC
Flash Point:400F,204C
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM, WATER FOG.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:CHEMTREC EMER PHONE #800-424-9300 (24 HR).
THIS MATL IS NOT EXPECTED TO PRESENT ANY ENVIRON PROBS OTHER THAN
THOSE ASSOC W/OIL SPILLS. STOP SOURCE OF LEAK/RELS. CLEAN UP RELS
AS SOON AS POSS. CONTAIN LIQ TO PVNT FURTHER CONTAM OF SOIL, SURF
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:READ ENTIRE DOCUMENT & LABEL BEFORE
USING THIS PRODUCT. AVOID PROLONGED OR FREQUENTLY REPEATED SKIN
CONTACT W/THIS MATERIAL.
Other Precautions:DO NOT WELD, HEAT OR DRILL CONTAINER. RESIDUE MAY
IGNITE W/EXPLOSIVE VIOLENCE IF HEATED SUFFICIENTLY. CAUTION! DO NOT
USE PRESSURE TO EMPTY DRUM OR EXPLOSION MAY RESULT.

Exposure Controls

Respiratory Protection:NO SPECIAL RESPIRATORY PROTECTION IS NORMALLY
REQUIRED. HOWEVER, IF OPERATING CONDITIONS CREATE HIGH AIRBORNE
CONCENTRATIONS, USE OF A NIOSH APPROVED RESPIRATOR IS RECOMMENDED.
Ventilation:USE ADEQUATE VENTILATION TO KEEP AIRBORNE CONCENTRATIONS OF
THIS MATERIAL BELOW RECOMMENDED EXPOSURE STANDARD.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EYE WASH FOUNTAIN & DELUGE
SHOWER . SKIN CONTACT CAN BE MINIMIZED BY WEARING PROTECTIVE
CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP PROD:CMPDS OF BORON. INCOMPLETE COMBUST CAN PRDCE CARBON
MONOXIDE. FIRST AID PROC:TREATMENT CENTER/HOSPITAL. SPILL
PROC:WATER/GROUNDWATER. CLEAN UP SM SPILLS USING APPROP TECHNIQUES
SUCH AS SORBENT MATLS/PUMPING. WHERE FEASIBLE & APPROP, REMOVE
CONTAM SOIL. FOLLOW PRESCRIBED PROCS FOR REPORTING & (ING 6)

Chemical Properties

Spec Gravity:0.91
Solubility in Water:INSOLUBLE
Appearance and Odor:AMBER TO DARK BROWN LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
MAY REACT W/STRONG OXIDIZING AGENTS, SUCH AS CHLORATES, NITRATES,
PEROXIDES, ETC.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NORMAL COMBUST FORMS CARBON DIOXIDE,
WATER VAP & MAY PRDCE OXIDES OF SULFUR & NITROGEN. COMBUST MAY
PRDCE TOX (SUPDAT)

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS . PLACE CONTAM MATLS IN DISPOSABLE CNTNRS & DISPOSE OF
IN MANNER CONSISTENT W/APPLICABLE REGS. CONTACT LOCAL ENVIRONMENTAL
OR HEALTH AUT HORITIES FOR APPROVED DISPOSAL OF THIS MATERIAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.